Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 25.40mm (0 ~ 1.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 50.80mm (0 ~ 2.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 762.00mm (0 ~ 30.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 6.35mm (0 ~ 0.25"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 609.60mm (0 ~ 24.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 76.20mm (0 ~ 3.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 304.80mm (0 ~ 12.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 101.60mm (0 ~ 4.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 76.20mm (0 ~ 3.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 101.60mm (0 ~ 4.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 203.20mm (0 ~ 8.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 457.20mm (0 ~ 18.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 152.40mm (0 ~ 6.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 50.80mm (0 ~ 2.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 25.40mm (0 ~ 1.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 254.00mm (0 ~ 10.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 152.40mm (0 ~ 6.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 381.00mm (0 ~ 15.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 457.20mm (0 ~ 18.00"), Sortida: 4mA ~ 20mA,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 381.00mm (0 ~ 15.00"), Sortida: 0 V ~ 10 V,
Per a la mesura: Linear Position, Tecnologia: LVIT (Linear Variable Inductance Transducer), Gamma lineal: 0 ~ 203.20mm (0 ~ 8.00"), Sortida: 4mA ~ 20mA,